Why Does Your Solar Battery Give Back Less Energy in Winter?

Why Does Your Solar Battery Give Back Less Energy in Winter

December, grey skies. You open the Zendure app and read: 1.5 kWh charged during the day, 0.8 kWh discharged in the evening. Where has the rest gone?

Rest assured, your battery is not faulty. In winter, several small losses add up, and they weigh more heavily than in summer because the battery moves so little energy. Below we explain where they come from, what they really cost and which settings keep them in check.

In winter, where do the kWh go that the battery does not give back?

A home battery never returns everything it takes in. The measure for this is round-trip efficiency: energy discharged divided by energy charged. For the SolarFlow 2400 AC+, we quote an AC round-trip efficiency of up to 96% from internal lab tests. For the SolarFlow Mix series it is around 90%, calculated from 95% each for charging and discharging, likewise measured in the lab.

In everyday use the figure is lower, especially at very low charging or discharging power. In winter, four losses come together in the home.

  • Conversion: Electricity is converted for the cells when charging and converted back when discharging. Each step costs a few per cent, and more at low power.
  • Self-consumption: Grid detection, Wi-Fi and the battery management system run day and night, even when the battery is neither charging nor discharging. In standby, the battery powers these components itself, which is why the state of charge can dip slightly below the set limit overnight.
  • Battery heating: If the cell temperature is close to 0°C and the battery needs to charge, the system first warms it to around 8°C, usually with grid electricity. If the battery sits in a cold garage or outdoors, this costs extra energy.
  • Control delay: If the battery charges from the surplus of another solar system and measures it through a meter such as a Shelly, it reacts with a short delay. In those seconds, a little electricity can flow to the grid instead of into the battery. We recommend switching off "Allow Excess Energy Export" in the HEMS Power Distribution Strategy. When charging from the grid, this makes no difference.

In summer these losses barely show, because the battery cycles many kWh every day. In winter it often charges little and at low power. The electronics' self-consumption still occurs every day, but is spread over fewer kWh. In frosty weather, battery heating comes on top. That is why losses take a bigger share in winter.

Why the same unit manages 84% in summer and 76% in winter

Part of the loss is fixed. The electronics use roughly the same amount whether the battery moves 5 kWh or 500 Wh a day. When the stored energy shrinks, this fixed share therefore weighs much more heavily.

On top of that, in winter the battery works at low power, with a small surplus at midday and a small load overnight. That is precisely where conversion is least efficient. One Hyper 2000 (Zendure's 2024 Products) owner who tracks their figures in Home Assistant sums it up: across the year it averages around 80%, rising to about 84% in summer and falling to about 76% in winter.

Let us look at each of these losses in turn, and at what you can do about them.

Zendure HEMS app showing dynamic prices, energy plans and household consumption

Standby consumption: the energy that keeps the unit ready

Even when it is neither charging nor discharging, your battery stays awake. It monitors the grid so it knows when to start again, and keeps the Wi-Fi active for the app. Its BMS, the electronics that watch over the cells, also constantly checks their voltage and temperature.

All of this needs a little energy, day and night. This is known as self-consumption or standby consumption.

Why the battery pays for its own standby

This energy comes mainly from the battery itself. The state of charge therefore drops slowly, even when the app shows neither charging nor discharging.

Our current models have the inverter built in, the device that turns battery power into electricity for the home. On older systems this inverter sat in a separate housing, and its consumption did not appear in the battery's figures.

What it costs over a winter

Connected to the grid, our units draw around 5 W in standby, sometimes only 3 to 4 W. Owners' own measurements point the same way: on a battery of around 2 kWh, many see a drop of 1 to 3% per day at rest.

For this calculation:

  • standby consumption: 5 W;
  • duration: 24 hours a day, over 120 winter days;
  • electricity price: 26.32p/kWh, the average unit rate under the Ofgem energy price cap for 1 October to 31 December 2026 (Direct Debit, England, Scotland and Wales).

Standby uses 0.12 kWh a day, so 14.4 kWh over the winter and around £3.80. That is not much. On a very dull day, when a small solar array produces just 0.5 kWh, it takes about a quarter of that. On other days, far less.

Standby on the grid is therefore not the biggest drain. The real difference comes from the off-grid port.

The AC off-grid port in Normal mode: around 20 to 25 W, non-stop

On models with an AC off-grid port, such as the SolarFlow 2400 AC+ and 2400 Pro, the port has three modes: Normal, Eco and Off. In Normal mode it is live at all times, even with nothing plugged in. At idle, the unit then draws around 20 to 25 W, four to five times as much as in grid standby.

One owner who uses this port measures the same: around 20 to 25 W overnight, or 300 to 400 Wh per winter night. Over 120 days that comes to 58 to 72 kWh, or around £15 to £19 at the average unit rate. This is the largest standby consumption you can avoid.

Eco mode solves the problem: if the port has no load for 2 hours, it goes into standby. And if you will not use it at all this winter, set it to Off.

A falling state of charge is not always real consumption

Beware of jumping to conclusions. The displayed state of charge is an estimate. Between two full charges it can drift by a few points and then correct itself in one go once the battery reaches 100%.

A battery that shows 10% less in the morning has therefore not necessarily used 10% overnight. Before measuring anything, let it charge fully once.

💡

Good to know

Standby consumption does not always appear in the app's statistics, which may then show 0 kWh of consumption. That is normal: this energy runs the unit rather than supplying the home. To estimate it, note the state of charge straight after a full charge and again 24 hours later, with no charging or discharging in between.

Conversion at low power: why 150 W costs more than 600 W

The second source of loss, and the most underrated: conversion. To get into the battery and back out to the home, electricity passes through the inverter, which changes its form. The efficiency of this conversion depends on the power at which the battery is working.

The reason is simple. The inverter has a fixed consumption whenever it is running. The more power it delivers, the smaller this fixed share becomes, and the better the conversion.

Take as an example a fixed share of 25 W while the unit is working. This figure illustrates the principle; it is not a measurement of any particular model:

  • at 600 W, these 25 W account for 4% of the power delivered;
  • at 300 W, it is 8%;
  • at 150 W, it rises to 17%.

In other words, the same conversion works markedly better at 600 W than at 150 W.

What you see in practice

The built-in inverters of compact home batteries lose efficiency when they only deliver a small amount of power, and this applies above all at night. Conversely, an inverter that runs at a steady, suitable output avoids these dips.

Owners who measure their units see the same trend. Efficiency rises markedly up to a few hundred watts and then levels off. Below that, it drops quickly.

At the other end, some losses grow with power. The stronger the current, the more the components heat up, and that heat is lost energy. That is why efficiency does not keep rising: at some point it reaches its ceiling.

Which leads to a tip: when you charge the battery from the grid, avoid low power and choose a high charging rate. This keeps conversion losses down.

Every model has its own curve, but the principle stays the same: a unit works best when it delivers a good share of its maximum output.

The overnight base load, the least favourable range

At night the house uses little, but without a break: fridge, router, devices on standby. This is the base load, and it is often 100 to 200 W.

This is exactly the range in which the battery works least efficiently. On a time-of-use or agile tariff, overnight is also usually the cheapest time of day. It is better to let the grid cover the overnight base load and save the battery for the evening and morning peaks.

Charging from a 50 W surplus achieves little

The same logic applies to charging. Small winter surpluses, such as 100 W around midday, enter the battery at modest efficiency and leave it in the evening with further losses. They remain useful, but deliver less than the figure suggests.

And when the battery charges from the surplus of another system, part of that small surplus never reaches it at all.

Charging from surplus: why around 50 W always flows to the grid

This third loss affects only one case: charging from the surplus of another system, for example a rooftop array with its own inverter. Your smart meter, such as the Smart Meter 3CT, measures what flows to the grid, and the battery takes up this surplus through its AC connection.

A protective buffer, not a fault

In this case the system does not regulate to 0 W at the meter. It lets around 50 W flow to the grid, and only the surplus above that goes into the battery. In practice:

  • with less than around 50 W of surplus, the battery does not charge;
  • with 200 W of surplus, around 50 W flows to the grid and 150 W into the battery;
  • the buffer remains in place for as long as charging continues.

This buffer is intentional. Switching between charging and discharging operates a relay, an electrical switch inside the unit. Without the buffer, every small change in consumption, such as the fridge starting up, would make the battery switch constantly and wear out the relay. There is no such buffer when discharging: the battery regulates to 0 W at the meter.

What this buffer means in winter

This charging method is designed for large rooftop arrays, which often deliver several hundred watts of surplus. At 1,000 W of surplus, 50 W accounts for only 5%. In winter the ratio changes.

For this calculation:

  • surplus on 4 hours a day, on 60 winter days;
  • buffer to the grid: 50 W;
  • electricity price: 26.32p/kWh.

The buffer accounts for at most 0.2 kWh a day, so 12 kWh over the winter and around £3.20 of electricity not stored. The amount stays small. But on a day when the surplus is 120 W, only 70 W goes into the battery, just under 60% of the surplus. And even if your supplier pays you for exported electricity, the export rate is usually well below what you pay for a unit from the grid.

Which Zendure unit loses least for your usage?

Not all of our batteries share the same design or output. The right unit is the one whose output matches what your home really uses, and which sends your electricity on the fewest detours.

AC coupling or direct solar input: how often is your electricity converted?

An AC-coupled battery connects to your home's AC wiring and takes up the surplus there. In the UK, Zendure specifies a hardwired installation by a Part P-registered electrician for both the SolarFlow 2400 AC+ and the 2400 Pro. The 2400 AC+ has no input for solar panels, so solar electricity changes form three times: in the panels' inverter, on entering the battery and on leaving it for the home.

The SolarFlow 2400 Pro, by contrast, has MPPT inputs. The MPPT is the controller that draws maximum power from the panels. Panels connected to it charge the battery directly with direct current: one conversion fewer, so fewer losses. On the 2400 Pro, this controller reaches an efficiency of 99.9%.

Choose the output for your base load, not your peak

Unit Panel connection Output to the home Which winter usage does it suit?
SolarFlow 2400 AC+ None: takes surplus through its AC connection Up to 2,400 W, hardwired Large rooftop array, evening use often above 300 W
SolarFlow 2400 Pro 4 MPPT inputs, plus charging through its AC connection Up to 2,400 W, hardwired Panels to connect and high evening use

A more powerful unit is not automatically better. A 2,400 W unit that supplies 150 W all night is working far from its ideal range. That is why, in winter, it pays to concentrate discharging into the hours when the house actually draws power, as described below. The extra headroom earns its keep when the house pulls 1,500 W while cooking.

Fewer units running, fewer losses

Many households have several batteries, added over the years. In summer that is an advantage. In winter, every unit that is switched on brings its own consumption, while the surplus available for storage has shrunk.

Several units in the same HEMS share the load

The HEMS is the system that controls your batteries in the app. When several units are connected to it, it spreads the demand equally. With two batteries and 600 W of consumption, each supplies 300 W. With three batteries and a 300 W base load, each supplies only 100 W.

Take the same example, with a fixed share of 25 W per working unit:

  • three units at 100 W each: 75 W of fixed share, so 25% of the demand covered;
  • a single unit at 300 W: 25 W of fixed share, so around 8%.

Over a winter night, the difference amounts to several hundred watt-hours for the same demand covered.

Pausing a unit over the winter

If your winter surplus does not even fill a single battery, you can keep just one unit active and pause the others until spring. The remaining unit then receives the whole surplus, reaches 100% more often and works at a more comfortable output. Leave it connected: it keeps its protective functions active all winter.

To pause a unit:

  • remove it from the HEMS in the app;
  • bring its battery to around 60%, the recommended level for longer storage;
  • switch it off following the procedure for your model, and have it isolated from the mains;
  • check the state of charge every three months and top it up to 60% if needed.

Store it somewhere dry and frost-free. Cold has its own rules: the lower the temperature at the installation site, the more often the battery has to warm itself before it can charge.

Removing expansion batteries

The same logic applies to expansion batteries. Each has its own monitoring electronics. If your capacity is well above what you can fill in winter, you can remove an expansion battery with the unit switched off and store it at 60%.

There is a second benefit: with less capacity, the battery reaches 100% more often, which keeps its state-of-charge display more accurate.

Let the battery work when demand is high

In the automatic modes, the battery follows consumption as closely as possible: it regulates to 0 W at the meter, whatever power is called for. So it may supply 120 W all night. In winter it can pay to concentrate discharging into the hours when the house uses a lot.

It is the same principle as with conversion: the inverter works better at a steady and sufficient output.

Choosing the right time slots with TOU or Custom

In TOU mode you divide the day into time slots. You can place discharging in the evening peak, for example from 6pm to 10pm, when cooking, lighting and screens all run at once. For the rest of the day you leave the battery on standby.

Custom mode goes further: it sets the discharge power for each time slot. Choose a value slightly below what the house really uses in that period. If the battery supplies more than the house needs, the rest flows to the grid.

This fits well with a time-of-use or agile tariff: electricity is usually cheapest overnight, which is exactly when the battery works least efficiently. Which tariff suits a solar battery best is covered in our guide to the best tariff for solar and battery in the UK.

🔧

Expert tip

Before setting your time slots, look at a week of consumption in the app. Find the hours when the house uses well above its base load, often between late afternoon and bedtime. In that window, every stored kWh is worth the most to you.

Raising the discharge limit

The discharge limit is the state of charge below which the battery stops supplying the home. In winter you can raise it, for example to 30 to 50%. The battery then stops earlier, at the time when demand is lowest, and keeps a reserve for the morning peak or a power cut.

Home Assistant for a limit in watts

If you use Home Assistant, a home automation platform, the Zendure integration goes further still. Some owners set up a simple rule there: the battery only discharges when the house needs more than a certain amount of power, for example 300 or 400 W.

It is best to let a single system control the battery. If Home Assistant is in charge, remove the battery from the HEMS in the app.

Measuring your system's real efficiency

Before changing your settings, measure your starting point. A single day tells you little: depending on the state of charge in the evening, the same unit can appear to return very little one day and much more the next.

Compare over a month, between two full charges

Take a period of at least a month that starts and ends straight after a full charge. Divide the energy discharged in that period by the energy charged. If you start and finish at the same state of charge, you do not count the energy left in the battery as lost.

Metering on the home side for an accurate reading

The app's statistics are enough to follow a trend. For a more precise measurement, have an energy meter fitted on the battery's circuit that counts energy in both directions. You then see what really flows in and out, standby included.

Frequently asked questions

My battery loses a few per cent a day when not in use. Is that normal?

Yes. Connected to the grid, the unit draws around 3 to 5 W in standby for its electronics, grid monitoring and Wi-Fi. On a battery of around 2 kWh, that is a few per cent a day. If the drop is much larger, first check whether the AC off-grid port is running in Normal mode, then charge the battery fully once to recalibrate the display.

Should I disconnect the battery in winter to save on standby?

Not if you only have one unit. Connected, it keeps its protective functions: cell monitoring, heating in the cold and protective charging if the state of charge drops too low. If you have several units, pause the ones winter does not need.

Can the 50 W to the grid be adjusted?

Not at present: this buffer is fixed. It only affects charging from the surplus of another system and protects the relay that switches the battery between charging and discharging. Over a winter it amounts to a few pounds.

Does charging from the grid in winter make up for these losses?

Rarely. The losses also apply to electricity you buy overnight, and they are higher at low power. Only large price gaps cover them comfortably, such as on windy winter days with an agile tariff.

In winter, every wasted watt matters more than every stored kWh

In winter your battery gives back less for three reasons: standby running day and night, low power that drags efficiency down, and the small buffer that flows to the grid when charging from surplus. None of them is a fault, and none of them costs a fortune on its own.

You can still reduce them: the AC off-grid port on Eco or Off, a single active unit when surplus is scarce, discharging concentrated into the evening peak, and a higher discharge limit. With these settings in place, every kWh you store this winter will count.