Two home batteries with the same starting capacity, the same AC power rating and the same app. On paper, the SolarFlow 2400 Pro and SolarFlow 2400 AC+ look so similar that it can be hard to know which to choose.
Start by looking at how your solar panels connect. The SolarFlow 2400 Pro has four maximum power point trackers (MPPTs) for connecting compatible panels directly. The SolarFlow 2400 AC+ is an AC-coupled retrofit battery. It stores surplus electricity from panels already connected to an inverter.
That difference matters when you first install solar, when you add to an existing array, and when you want to charge the battery away from the grid.
Do you need to connect solar panels directly?
If you are buying panels and a battery together, or adding panels in a garden, on a terrace or on a carport, the SolarFlow 2400 Pro can take their DC output directly. Those panels can feed the battery without a separate microinverter.
If your rooftop solar panels already generate electricity through an inverter, the SolarFlow 2400 AC+ can store their surplus on the AC side of your system. Your original inverter stays in place. A qualified electrician hardwires the battery to your consumer unit.
Choose based on the solar you already have and any panels you plan to add. In the UK, both models require professional hardwired installation for grid-connected home use.
SolarFlow 2400 Pro for direct solar input with four MPPTs
Four independent trackers with up to 3,000 W of DC input
The SolarFlow 2400 Pro accepts up to 3,000 W of direct DC solar input across four 750 W MPPT channels. It can accommodate up to eight compatible panels, depending on their electrical ratings and how the array is configured.
The individual trackers are useful when panels face different directions or shade moves across the site. An east-facing group can catch the morning sun while a south-facing group does more of the work around midday. On separate trackers, each group can operate at its own best point as the light changes.
14 V start-up for low-light conditions
The MPPTs have a 14 V start-up voltage. If the panels reach that threshold, the system can begin harvesting energy in weaker light, such as early in the morning, late in the afternoon or on an overcast day.
A lower start-up voltage can extend the part of the day in which the panels generate usable power. The gain over a season depends on the panels, their orientation and how much shade they get.
Up to 4,800 W of combined solar input
The 2400 Pro can combine up to 3,000 W of direct DC solar input with up to 1,800 W of AC-coupled solar input from a compatible external PV inverter, for up to 4,800 W in total. This combined figure refers to solar input. The battery's bidirectional AC power is rated separately.
If you already have solar and want to add more panels, an installer can assess whether the 2400 Pro can use your existing generation on the AC side and accept the new panels directly. To reach the combined input rating, the installer configures the off-grid port for a compatible PV inverter in a grid-connected setup. This uses the port as an input. Zendure lists 2,400 W as the maximum combined battery charging power.
Direct solar input
SolarFlow 2400 Pro
Connect compatible solar panels directly and store the electricity they generate.
- Four independent MPPTs, up to 3,000 W DC
- Up to 4,800 W combined DC and AC solar input
- 14 V start-up for low-light conditions
- 2,400 W bidirectional AC and 2.4–16.8 kWh storage
- 2,400 VA off-grid output, IP65 and ZenGuard™
SolarFlow 2400 Pro →
SolarFlow 2400 AC+ for adding storage to existing rooftop solar
Keep your existing panels and inverter
The SolarFlow 2400 AC+ works on the AC side of your system. When a compatible current transformer (CT) sensor or smart meter detects surplus solar electricity flowing towards the grid, it can tell the battery to charge. The stored electricity can then help supply your home when demand rises later in the day.
The retrofit normally leaves the roof, DC cabling and existing inverter in place. AC coupling can work alongside a range of microinverters, string inverters and hybrid inverters. Ask your installer to check the metering and controls, particularly if the existing system already includes a battery or limits exports.
After installation and commissioning, you can use the Zendure app to select operating modes and monitor the battery over Wi-Fi. The RJ45 socket is for RS485 communication with supported equipment.
Use more of the solar you already generate
Many homes have rooftop solar panels that generate more than the household uses around midday. A battery can store part of that surplus for the evening. If you are on a Smart Export Guarantee (SEG) tariff in Great Britain, compare what your supplier pays for exports with what you pay to import electricity later. The difference between the two rates, together with energy lost during charging and discharging, helps determine the value of storage. Ofgem's Smart Export Guarantee guidance explains who can take part.
The SolarFlow 2400 AC+ was designed for this kind of retrofit. If you are weighing up capacity and costs, see our UK guide to whether a solar battery is worth it.
AC-coupled retrofit
SolarFlow 2400 AC+
Add battery storage to an existing solar installation and keep the inverter you already use.
- AC coupling for existing solar installations
- Hardwired to the consumer unit by an electrician
- 2,400 W bidirectional AC and 2.4–16.8 kWh storage
- 2,400 VA off-grid output with fast switchover
- IP65, self-heating, ZenGuard™ and a 10-year warranty
SolarFlow 2400 AC+ →
SolarFlow 2400 Pro and SolarFlow 2400 AC+ specifications
| Specification |
SolarFlow 2400 Pro |
SolarFlow 2400 AC+ |
| Direct DC solar input |
3,000 W across four MPPTs (4 × 750 W) |
None |
| Panels connected directly |
Up to 8 compatible panels |
— |
| MPPT start-up voltage |
14 V |
— |
| Solar input |
Up to 4,800 W combined (3,000 W DC + 1,800 W AC) |
AC-coupled, up to 2,400 W charging power |
| Base battery capacity |
2.4 kWh |
2.4 kWh |
| Maximum battery capacity |
16.8 kWh with five AB3000L expansion batteries |
16.8 kWh with five AB3000L expansion batteries |
| Bidirectional AC power |
Up to 2,400 W |
Up to 2,400 W |
| UK grid connection |
Professionally hardwired to the consumer unit |
Professionally hardwired to the consumer unit |
| Dedicated off-grid output |
2,400 VA (up to 3,200 W with grid assistance) |
2,400 VA (up to 3,200 W with grid assistance) |
| Backup switchover |
Approximately 15 ms |
Approximately 15 ms |
| Battery chemistry |
LiFePO₄ (48 V / 50 Ah) |
LiFePO₄ (48 V / 50 Ah) |
| Rated cycle life |
6,000+ cycles |
6,000+ cycles |
| Ingress protection |
IP65 |
IP65 |
| Operating temperature range |
−20°C to 55°C |
−20°C to 55°C |
| Base unit dimensions |
326 × 294 × 251 mm |
326 × 294 × 251 mm |
| Base unit weight |
Approx. 28 kg |
Approx. 28 kg |
| Connectivity |
RS485 via RJ45, Wi-Fi and Bluetooth |
RS485 via RJ45, Wi-Fi and Bluetooth |
| Energy management |
Zendure HEMS, ZENKI and MQTT support |
Zendure HEMS, ZENKI and MQTT support |
| Warranty |
10 years |
10 years |
The models share their base capacity, AC power rating and expansion options. The first four rows show where your choice makes a practical difference.
🔧
Installer's tip
Direct DC solar charging avoids converting panel output to AC and then back to DC before storage. With AC coupling, those extra conversions use some energy, but they let you add storage while keeping an existing solar inverter and its DC wiring.
What the two batteries have in common
2,400 W bidirectional AC power and 2.4–16.8 kWh of storage
Both models can charge or discharge at up to 2,400 W through the AC connection in a suitably configured installation. That charging power helps capture a short midday surplus. When the battery discharges, the amount it can cover depends on what else is running. Two appliances drawing 1,200 W and 800 W at the same time would use 2,000 W of the rated output. Other loads may bring total demand above what the battery can supply.
Each model starts with 2.4 kWh of storage. You can add up to five 2.88 kWh AB3000L batteries to reach 16.8 kWh. You can also start with the base unit and expand if your generation and consumption justify it.
💡
UK installation and grid connection
For grid-connected use, have a qualified electrician hardwire either model to the consumer unit and follow the electrical and building requirements for your location, including Part P where applicable. Great Britain's plug-in solar framework covers compliant plug-in solar devices. These home batteries require the fixed installation described above.
Ask your installer to check the full system, including any existing solar inverter, and confirm the applicable connection process with your distribution network operator (DNO). This could involve a G98 notification or a G99 application. Your installation may also have a separate export limit. See our G98 and G99 guide and the government guidance on registering solar and storage.
A dedicated socket for backup power
Both models have a dedicated off-grid socket rated at 2,400 VA. When the backup function is enabled, it can switch to battery power in about 15 milliseconds during a power cut. It supplies appliances connected to that socket, such as a fridge, router or lamp, within its rated output.
With mains power available, the socket can support loads of up to 3,200 W in grid-assisted operation. Normal mode keeps the output available, subject to the battery's charge and operating limits. Eco Mode switches the output off after two hours without a detected load.
The same energy management system
Both batteries use Zendure's Home Energy Management System (HEMS) and can be managed through the Zendure app. ZENKI can use weather forecasts, household consumption and supported electricity prices to plan when to charge and discharge.

If you have a compatible time-of-use tariff, you can use cheaper off-peak periods to charge and draw on the battery when electricity costs more. Check your exact tariff in the app. How much you save depends on your rates, how much solar you export, and how you use the battery.
Both models also support MQTT for compatible smart-home setups and can work with selected third-party devices. Check compatibility for the specific meter, tariff or equipment you use.
Shared battery safety features
Both batteries use lithium iron phosphate (LiFePO₄) cells and Zendure's ZenGuard™ protection. This includes dual battery management systems, self-heating to bring cold cells into their charging range, and a condensed aerosol fire suppression system for severe thermal faults.
Both units are IP65-rated for protection against dust and water jets and have an operating temperature range of −20°C to 55°C. Follow the installation manual when choosing a location, including the requirements for clearance and exposure. The operating range and the permitted cell charging range are separate specifications.
Using either battery away from home
The dedicated off-grid socket can also supply appliances from stored energy at a location without mains power. The main practical question is whether you can top up the battery with solar while you are there.
Solar charging on a motorhome trip or at a campsite
For occasional off-grid use, the SolarFlow 2400 Pro can charge from compatible portable solar panels connected directly to its MPPT inputs. Check the panel ratings against the manual, including open-circuit voltage in cold weather and the current limit for each input. If you want to use panels fixed to a motorhome, have the installer check the vehicle's electrical system and the proposed connection.
The 14 V start-up threshold can help the Pro begin charging in weaker light. For a trip lasting several days, size the panels and battery around the appliances you actually use and the solar conditions you expect.
The SolarFlow 2400 AC+ can supply appliances off-grid from a charge stored before departure. It has no direct DC input for portable panels. For grid charging, follow the UK manual and use the connection arrangement specified for the unit.
What can the 2,400 VA off-grid socket power?
The socket on either model can supply loads such as a portable fridge, lights or a projector. Check the combined load and the starting demand of appliances with a motor or compressor. Each unit has a single off-grid socket. Use only accessories approved for the UK model and keep total demand within the socket's rating.
Plan for 2,400 VA when running on battery power alone. The 3,200 W figure applies when the mains supply can assist. Normal mode keeps the output available for loads that cycle on and off, such as a fridge. Eco Mode can switch the output off if there is no detected load for two hours.
Self-heating can help bring the battery into its charging range on a cold morning. Allow for the conditions on site and follow the manual's temperature limits.
What to consider before travelling
Each base unit weighs around 28 kg before you add expansion batteries. If you move a standalone unit, plan how you will lift and secure it, and follow Zendure's transport instructions. A fixed installation should be disconnected by an electrician before it is moved.
At your destination, use a stable location and protect the unit from direct summer sun and standing water, in line with the manual.
Which SolarFlow 2400 suits your setup?
Choose the SolarFlow 2400 Pro if…
- You are buying solar panels and battery storage as part of the same project.
- You want to add compatible panels on a balcony, terrace, garden frame or carport and connect them directly to the battery.
- Your new panels will face different directions or receive different amounts of shade.
- Low-light start-up matters for your installation, especially in winter.
- You already have solar and want to add panels on a separate direct DC input.
- You plan to use compatible portable panels with a standalone battery while away from mains power.
Choose the SolarFlow 2400 AC+ if…
- Your rooftop solar already generates electricity through an existing inverter.
- You want to leave the roof and existing DC wiring in place.
- You export surplus solar during the day and want to see whether storing it for later would offer better value.
- You want a retrofit battery and have no plans to connect additional panels directly.
- You would like to keep your existing inverter, subject to the installer's checks.
- Your main use is at home, with any occasional standalone use based on energy stored beforehand.
You already have rooftop solar and want to add panels
You might have a working rooftop array and room for a few more panels on a shed or garden frame. The 2400 Pro can take the new panels on its MPPT inputs while using existing solar generation through a compatible AC-coupled setup. Ask your installer to assess the combined system and confirm the grid connection requirements before work starts.
If you plan to keep your existing array as it is, the 2400 AC+ provides the AC-coupled storage you need. The Pro's MPPTs become useful when there are compatible panels to connect to them.
Conclusion
Choose the SolarFlow 2400 Pro if you want to connect new panels directly. Choose the SolarFlow 2400 AC+ if you want to store surplus electricity from an existing inverter and have no plans to add direct DC solar. For occasional off-grid use, the same distinction determines whether you can recharge directly from portable panels.
Both start at 2.4 kWh, expand to 16.8 kWh, offer up to 2,400 W of bidirectional AC power and come with a 10-year warranty. If your project involves adding panels or changing the way solar is exported, confirm the proposed setup with your installer.
Frequently asked questions
What is the main difference between the SolarFlow 2400 Pro and 2400 AC+?
The 2400 Pro has four MPPTs for up to 3,000 W of direct DC solar input. A compatible AC-coupled inverter can bring its total solar input up to 4,800 W. The 2400 AC+ uses AC coupling to store surplus from an existing inverter, with up to 2,400 W of charging power. Both offer the same base capacity and expansion limit.
Is the SolarFlow 2400 Pro worth it if I already have an inverter?
The Pro is useful if you also plan to add panels and connect them directly. For a straightforward retrofit where all your panels already feed an existing inverter, the 2400 AC+ provides the AC-coupled storage you need.
Can I connect solar panels directly to the SolarFlow 2400 AC+?
The 2400 AC+ requires AC power from a compatible solar inverter. For new panels that you want to connect directly to the battery, choose the 2400 Pro and check that the panels match its MPPT input ratings.
Can I keep my existing rooftop solar inverter?
Usually, yes. An AC-coupled retrofit on the household side of the inverter generally lets you keep your existing string inverter or microinverters. Your installer should check metering compatibility, export controls and how any existing battery is configured.
Is a SolarFlow battery useful if my panels produce little surplus?
Start by comparing your daytime solar generation with your household use over the same hours. If the gap is small, you may get enough benefit from the 2.4 kWh base unit. Both models can also charge from the grid during an off-peak period. Whether that saves money depends on the difference between your peak and off-peak import rates and the energy lost in each charge and discharge cycle.
Can I take either battery camping or use it on a motorhome trip?
Both can supply suitable appliances from their dedicated 2,400 VA socket when used standalone. The 2400 Pro can also recharge from compatible portable solar panels. With the 2400 AC+, plan around the energy stored before you leave. Allow for a weight of around 28 kg per base unit and follow the transport and installation instructions.
Can I install either battery outside?
Both are IP65-rated and have an operating range of −20°C to 55°C. Follow the manual's siting and clearance requirements. A sheltered location out of direct sun helps reduce heat exposure, and the built-in heater can bring cold cells into their permitted charging range.
Leave a comment