Solar panels in winter: what low sun, snow and frost mean for your system

Solar Panels in Winter

From December to February, the sun over Britain sits lower and stays up for a shorter time than in any other season. Every solar system feels it straight away: output drops, and shade, snow and frost have more say than in summer over how much electricity actually reaches your home.

The short answer: solar panels in winter produce less, but they produce it reliably. A south-facing roof at 35 degrees in central England generates on average around 1.07 kWh per kWp per day in December, against around 3.9 kWh in June, so June delivers not quite four times as much.

But why exactly, and how does output change over a winter's day? Which orientation, tilt and additional panels make the most difference in the dark months, and what should you watch out for with snow and frost?

Why does a solar PV system produce less in winter?

First, the days are short: on 21 December, Birmingham (52.5 degrees north) gets only around 7 hours 40 minutes of daylight, against almost 17 hours on 21 June. Second, the sun sits low. At noon on the winter solstice it climbs only about 14 degrees above the horizon in Birmingham, around 15 degrees in London and barely 11 in Edinburgh, while in June it reaches about 61 degrees in Birmingham.

At such a shallow angle the light is spread over a larger area, and its path through the atmosphere is around four times longer than with the sun directly overhead, so haze and cloud absorb more of it. Then there is the weather: grey days with mostly diffuse light are the norm in winter.

Long shadows in winter

A low sun lengthens every shadow. In Birmingham, an obstacle at noon on 21 December casts a shadow about four times its own height, against just over half its height in June. A ten-metre tree therefore casts a shadow of around 40 metres at midday, and an even longer one in the morning and afternoon.

Bare branches cast shade too, and chimneys or dormers now reach rows of panels that stay clear in summer. Because the panels in a string are wired in series, a single partly shaded panel can pull down the whole string. Bypass diodes and power optimisers limit this loss. Here is how to spot winter shade:

  • Photos around midday: On a clear December day, photograph the roof at 10am, noon and 2pm, and the shadow edges will be easy to see.
  • Compare your monitoring: If one string delivers noticeably less than the other on clear days, shade or snow is the likely cause.
  • Check new areas in advance: A surface that is in full sun in June can lie in shade in December.

How does solar output change over a winter's day?

In December, generation is squeezed into a few hours. According to the daily profile from PVGIS, the European Commission's solar calculator (Birmingham, radiation data 2005 to 2023, retrieved in November 2026), a south-facing roof at 35 degrees only receives meaningful light between about 9am and 3pm. Almost three-quarters of the day's irradiation falls in the four hours around midday.

For a solar system's winter output, that means the average midday irradiance in December is around 250 W/m², against around 580 W/m² in June. A 10 kWp system reaches about 2.2 kW at midday on an average December day, and around 5 kW in June.

The average hides a wide range, though. For a clear December day, PVGIS's clear-sky model gives around 590 W/m² at midday. The 10 kWp system then reaches about 5 kW for a few hours, roughly what it manages on an average June day, and produces roughly 25 kWh instead of the average 10.7 kWh. Running the washing machine or dishwasher in those midday hours puts scarce winter electricity straight to use in the home.

Which orientation and tilt work best in winter?

In winter, facing south matters more than in summer. According to PVGIS, an east- or west-facing roof at 35 degrees delivers only around two-fifths of a south-facing roof's output in December. Steeper surfaces catch the low sun better but give up some output in summer, as the figures for Birmingham show:

Surface December, kWh per kWp per day Full year, kWh per kWp
South, 30 degrees 1.00 960
South, 35 degrees 1.07 968
South, 60 degrees 1.31 929
South, vertical (wall) 1.30 710
East, 35 degrees 0.44 775
West, 35 degrees 0.44 756

At 60 degrees, panels deliver around 31 per cent more than at 30 degrees in December, but lose just over 3 per cent across the year. On clear December days the lead is larger still: the clear-sky profile shows over a quarter more daily irradiation at 60 degrees than at 35. On a pitched roof the angle is fixed; there is more scope with frames on flat roofs, in the garden or on walls.

If you use adjustable frames, you can tilt the panels more steeply from November to February. The gain remains modest: switching from 30 to 60 degrees for those four months only adds around 36 kWh per kWp a year, just under 4 per cent.

Add panels where the winter sun reaches

The surest way to more winter electricity is additional panel area in the right place. Vertical south-facing surfaces on a wall, balcony railing or fence deliver around 1.3 kWh per kWp per day in December, more than a 35-degree south roof, and snow hardly settles on them. Over the year they only reach around 710 kWh per kWp, but a quarter of that falls between November and February.

An east–west roof with 5 kWp on each side produces around 4.4 kWh a day in December on average. Adding 2 kWp on a south-facing wall gives around 2.6 kWh more, well over half as much again. Adding panels to an existing string raises its voltage, though; more on that below. It is often simpler to connect the new array through its own microinverter on the AC side.

The SolarFlow 2400 AC+ is an AC-coupled battery that connects to an existing rooftop system without any changes to its DC wiring. In the UK, it is hardwired to the consumer unit by a Part P-registered electrician and is certified to ENA G98. With up to 2,400 W of charging and discharging power, it can supply several power-hungry appliances at once at peak times. It stores the surplus from bright winter days with a base capacity of 2.4 kWh, expandable to 16.8 kWh, and releases it in the evening. Whether a battery pays off for your home is covered in our guide are solar batteries worth it?

Zendure SolarFlow 2400 AC+

Snow on the panels: clear it or leave it?

A thin layer of snow still lets some light through; a full blanket largely stops generation. In much of lowland Britain lying snow is short-lived, and on pitched roofs it usually slides off once the dark panels warm in the sun. The loss stays small: if a 10 kWp south-facing system spends a whole week in January under snow, PVGIS averages put the shortfall at around 84 kWh, less than 1 per cent of its annual yield.

The snow that slides off deserves more attention. From smooth panel surfaces it often comes away in one piece and drops onto paths, doorways or cars. Snow guards along the eaves hold it back. If you do decide to clear the panels, these rules apply:

  • From the ground only: A soft brush or a snow rake with a rubber edge on a telescopic pole is enough for low-mounted panels.
  • Never climb onto the roof: Snowy and icy panels are extremely slippery; clearing on the roof is a job for a professional with proper fall protection.
  • No hot water, no salt: The thermal shock can damage the glass, and rock salt and de-icers attack frames and seals.
  • No hard tools: Scrapers and metal edges scratch the glass surface for good.

How much load a panel can take is given in pascals on its datasheet. Whether your roof and mounting system can carry that is a question for your installer when heavy, wet snow builds up.

Why does panel voltage rise in frost, and what does it mean for the inverter?

At first, cold is an advantage for solar cells. At the same time, though, the voltage rises too, including the open-circuit voltage (Voc) that a panel produces with no load connected.

Why does that matter? In the morning, before the inverter starts exporting, exactly this open-circuit voltage sits at its input. On a clear frosty morning, the sun hits panels that are still as cold as the air. If the voltage then exceeds the inverter's maximum input voltage, the inverter can shut down or be damaged.

A worked example with the same panel: its open-circuit voltage is 35.03 V at 25°C, with a temperature coefficient of −0.25% per degree. At −10°C, a realistic frosty morning in much of the UK, it rises by 8.75% to around 38.1 V; in an exceptional cold snap at −20°C, to around 39.0 V. If the inverter accepts at most 1,000 V, 27 panels in series reach 946 V at 25°C, but around 1,029 V at −10°C. With 26 panels, the string stays just below the limit at −10°C (990 V), but not at −20°C, at around 1,013 V.

Important: The minimum design temperature for your site is set by your installer. Two limits need checking: the inverter's maximum input voltage and the panels' maximum system voltage, which is 1,500 V DC for the example panel. The lower of the two applies.

It is worth recalculating the cold open-circuit voltage in these cases in particular:

  • Adding panels: Every extra panel in a string raises its voltage by that panel's own open-circuit voltage.
  • Changing panel type: New panels with a higher Voc change the calculation, even with the same number of panels.
  • Replacing the inverter: The new unit may have a different maximum input voltage and a different MPP range.
  • Microinverters: Here the limit per input from the datasheet applies, calculated with the cold open-circuit voltage of the connected panels.

Frequently asked questions about solar panels in winter

Does the inverter limit depend on the MPP voltage or the open-circuit voltage?

For the maximum input voltage, what counts is the open-circuit voltage at the lowest expected temperature. The MPP voltage (Vmp) determines whether the string sits within the tracker's operating range. It is always lower than the Voc and does not set the upper limit.

Do solar panels generate electricity when it is overcast?

Yes, from diffuse light, though considerably less. The PVGIS monthly averages already include grey days. On a clear December day, the daily irradiation on a 35-degree south roof reaches more than twice the average.

When does output start to rise again?

Slowly from January, and clearly from February. According to PVGIS, a 35-degree south roof delivers around 1.8 kWh per kWp per day in February, around 70 per cent more than in December, and around 2.7 kWh in March.

Conclusion: solar panels in winter, realistic expectations and targeted improvements

In December, a south-facing system produces only just over a quarter of its June daily yield, concentrated around midday. Short days, a low sun and long shadows are to blame, while the cold actually improves efficiency.

The biggest gains come from panel area. Facing south, steeper angles and additional vertical south-facing surfaces deliver noticeably more in December, though some of them cost output over the year. Snow usually costs only a few days, and if it is cleared at all, that is done from the ground.

Frost, meanwhile, deserves attention at the planning stage. Anyone adding panels or replacing an inverter should have the open-circuit voltage recalculated for the lowest temperature at their site. All in all, by keeping an eye on shade, tilt and voltage, you get the most out of the short winter days.